    "document": {
      "category": "csaf_security_advisory",
      "csaf_version": "2.0",
      "tracking": {
        "generator": {
          "date": "2025-03-21T11:47:01.298Z",
          "engine": {
            "version": "2.5.21",
            "name": "Secvisogram"
          }
        },
        "id": "VDE-2022-011",
        "version": "1",
        "status": "final",
        "aliases": [
          "VDE-2022-011"
        ],
        "revision_history": [
          {
            "number": "1",
            "summary": "initial revision",
            "date": "2022-09-07T12:50:00.000Z"
          }
        ],
        "current_release_date": "2022-09-07T12:50:00.000Z",
        "initial_release_date": "2022-09-07T12:50:00.000Z"
      },
      "lang": "en-GB",
      "title": "MB connect line: Unauthenticated user enumeration in mbCONNECT24 and mymbCONNECT24",
      "acknowledgments": [
        {
          "organization": "CERTVDE",
          "urls": [
            "https://certvde.com"
          ],
          "summary": "coordination"
        },
        {
          "organization": "SySS GmBH",
          "summary": "reporting",
          "urls": [
            "https://www.syss.de"
          ]
        },
        {
          "organization": "Helmholz",
          "summary": "reporting",
          "urls": [
            "https://www.helmholz.de"
          ]
        }
      ],
      "distribution": {
        "tlp": {
          "label": "WHITE",
          "url": "https://www.first.org/tlp/"
        }
      },
      "notes": [
        {
          "category": "summary",
          "title": "Summary",
          "text": "An issue was discovered in the mymbCONNECT24 and mbCONNECT24 software in all versions through V2.11.2."
        },
        {
          "category": "description",
          "title": "Impact",
          "text": "A remote, unauthenticated attacker can enumerate valid users with a timing attack against the webserver."
        },
        {
          "category": "description",
          "title": "Remediation",
          "text": "Update to Version 2.12.1"
        }
      ],
      "publisher": {
        "category": "vendor",
        "contact_details": "security-team@mbconnectline.de",
        "name": "MB connect line GmbH",
        "namespace": "https://mbconnectline.com"
      },
      "references": [
        {
          "summary": "VDE-2022-011: MB connect line: Unauthenticated user enumeration in mbCONNECT24 and mymbCONNECT24 - HTML",
          "url": "https://certvde.com/de/advisories/VDE-2022-011/",
          "category": "self"
        },
        {
          "category": "external",
          "summary": "CERT@VDE Security Advisories for ",
          "url": "https://certvde.com/en/advisories/vendor/mbconnectline/"
        },
        {
          "summary": "VDE-2022-011: MB connect line: Unauthenticated user enumeration in mbCONNECT24 and mymbCONNECT24 - CSAF",
          "url": "https://mbconnectline.csaf-tp.certvde.com/.well-known/csaf/white/2022/vde-2022-011.json",
          "category": "self"
        }
      ]
    },
    "product_tree": {
      "branches": [
        {
          "category": "vendor",
          "name": "MB connect line GmbH",
          "branches": [
            {
              "category": "product_family",
              "name": "Hardware",
              "branches": [
                {
                  "category": "product_name",
                  "name": "mbCONNECT24",
                  "product": {
                    "name": "mbCONNECT24",
                    "product_id": "CSAFPID-11001"
                  }
                },
                {
                  "category": "product_name",
                  "name": "mymbCONNECT24",
                  "product": {
                    "name": "mymbCONNECT24",
                    "product_id": "CSAFPID-11002"
                  }
                }
              ]
            },
            {
              "category": "product_family",
              "name": "Firmware",
              "branches": [
                {
                  "category": "product_version_range",
                  "name": "<=2.11.2",
                  "product": {
                    "name": "Firmware <=2.11.2",
                    "product_id": "CSAFPID-21001"
                  }
                },
                {
                  "category": "product_version",
                  "name": "2.12.1",
                  "product": {
                    "name": "Firmware 2.12.1",
                    "product_id": "CSAFPID-22001"
                  }
                }
              ]
            }
          ]
        }
      ],
      "relationships": [
        {
          "category": "installed_on",
          "product_reference": "CSAFPID-21001",
          "relates_to_product_reference": "CSAFPID-11001",
          "full_product_name": {
            "name": "Firmware <=2.11.2 installed on mbCONNECT24",
            "product_id": "CSAFPID-31001"
          }
        },
        {
          "category": "installed_on",
          "product_reference": "CSAFPID-22001",
          "relates_to_product_reference": "CSAFPID-11001",
          "full_product_name": {
            "name": "Firmware 2.12.1 installed on mbCONNECT24",
            "product_id": "CSAFPID-32001"
          }
        },
        {
          "category": "installed_on",
          "product_reference": "CSAFPID-21001",
          "relates_to_product_reference": "CSAFPID-11002",
          "full_product_name": {
            "name": "Firmware <=2.11.2 installed on mymbCONNECT24",
            "product_id": "CSAFPID-31002"
          }
        },
        {
          "category": "installed_on",
          "product_reference": "CSAFPID-22001",
          "relates_to_product_reference": "CSAFPID-11002",
          "full_product_name": {
            "name": "Firmware 2.12.1 installed on mymbCONNECT24",
            "product_id": "CSAFPID-32002"
          }
        }
      ],
      "product_groups": [
        {
          "group_id": "CSAFGID-0001",
          "summary": "affected products",
          "product_ids": [
            "CSAFPID-31001",
            "CSAFPID-31002"
          ]
        },
        {
          "group_id": "CSAFGID-0002",
          "summary": "fixed products",
          "product_ids": [
            "CSAFPID-32001",
            "CSAFPID-32002"
          ]
        }
      ]
    },
    "vulnerabilities": [
      {
        "cve": "CVE-2022-22520",
        "title": "CVE-2022-22520",
        "product_status": {
          "known_affected": [
            "CSAFPID-31001",
            "CSAFPID-31002"
          ],
          "fixed": [
            "CSAFPID-32001",
            "CSAFPID-32002"
          ]
        },
        "scores": [
          {
            "cvss_v3": {
              "attackVector": "NETWORK",
              "attackComplexity": "LOW",
              "privilegesRequired": "NONE",
              "userInteraction": "NONE",
              "scope": "UNCHANGED",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "availabilityImpact": "NONE",
              "version": "3.1",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "temporalScore": 5.3,
              "temporalSeverity": "MEDIUM",
              "environmentalScore": 5.3,
              "environmentalSeverity": "MEDIUM"
            },
            "products": [
              "CSAFPID-31001",
              "CSAFPID-31002"
            ]
          }
        ],
        "notes": [
          {
            "category": "summary",
            "text": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
          }
        ],
        "remediations": [
          {
            "category": "vendor_fix",
            "details": "Update to Version 2.12.1",
            "group_ids": [
              "CSAFGID-0001"
            ]
          }
        ],
        "cwe": {
          "id": "CWE-204",
          "name": "Observable Response Discrepancy"
        }
      }
    ]
  }